  Datasheet File OCR Text:
  specification TN-3000-112 tn-3000 -124 tn-3000 -148 tn-3000 -212 tn-3000 -224 tn-3000 -248 200 / 220 / 230 / 240vac selectable by setting button s.w 50 0.1hz 50/60hz selectable by setting button s.w 150a 24v 21 ~ 30vdc 90% 75a 48v 42 ~ 60vdc 91% 150a 24v 21 ~ 30vdc 91% 75a 48v 42 ~ 60vdc 92% model maximum output power waveform output frequency ac regulation (typ.) transfer time (typ.) front panel indicator saving mode (typ.) no load dissipation (typ.) bat. voltage off mode draw current voltage range note.5 efficiency (typ.) note.1 dc current (typ.) note.3 input input protection battery output fuse safety & emc bat. low alarm note.5 bat. low shutdown note.5 over temperature output short reverse polarity gfci proctection 100 / 110 / 115 / 120vac selectable by setting button s.w 3450w for 180 sec. / 4500w for 10 sec. / surge power 6000w for 30 cycles true sine wave (thd<3%) at rated input voltage 60 0.1hz 50/60hz selectable by setting button s.w 300a 12v 10.5 ~ 15vdc 89% 40a*12 40a*6 20a*6 20a*6 40a*6 11.3v 22.5v 45v 45v 22.5v 10.5v 21v 42v 42v 21v 3% t<10ms inverter by pass load 5w will be changed to standby mode battery voltage level, output load level, saving mode, fault and operat ion status 10w @ standby saving mode 12v 1ma 10.5 ~ 15vdc 88% 300a 40a*12 11.3v 10.5v protection type : shut down o/p voltage, re-power on to recover protection type : shut down o/p voltage, re-power on to recover by internal fuse open optional (only type f) none ac input: 20a, ac output receptacle: 15a emi conduction&radiation ems immunity compliance to fcc class a none working temp. note.2 working humidity storage temp., humidity safety standards 0 ~ +40 @ 100% load ; 60 @ 50% load 20% ~ 90% rh non-condensing -30 ~ +70 / -22 ~ +158 f, 10 ~ 95% rh o ul458 (only for "gfci" receptacle-type f ) compliance to en61000-4-2,3,4,5,6,8,11 env50204 compliance to en55022 class a, 72/ 245/ cee, 95/ 54/ ce, e-mark true sine wave output (thd<3%) u.p.s. mode and energy saving mode (selectable) power on-off switch standby saving mode can be selectable front panel indicator for operation status thermostatically controlled cooling fan protections: bat. low alarm / bat. low shutdown / over voltag e / over temp. / output short / input polarity reverse / overload / ac circui t breaker application : home appliance, power tools, office and porta ble equipment, vehicle and yacht ...etc. built-in solar / ac charger optional monitoring software 3 years warranty high surge power up to 6000w high efficiency up to 92% rated power (typ.) 3000w 3000w 3000w 3000w 3000w 3000w battery types open & sealed lead acid over load (typ.) circuit breaker 105 ~ 115% load for 180 sec., 115% ~ 150% load for 10 sec. protection type : shut down o/p voltage, re-power on to recover ac input: 40a, ac output receptacle:15a withstand voltage bat i/p - ac i/p:3.0kvac bat i/p - ac o/p:3.0kvac ac o/p - fg:1.5kvac vibration 10 ~ 500hz, 3g 10min./1cycle, 60min. each along x, y, z axes features : 3000w true sine wave dc-ac inverter with solar charger t n - 3 0 0 0 s e r i e s max open circuit voltage charge current (typ.) charge current (max.) charge voltage note.5 charge voltage note.5 25v 25a 30a 14.3v 14.3v solar charger ac charger 28.5v 28.5v 12a 75v 57v 57v 6a 45v 28.5v 28.5v 12a 75v 57v 57v 6a 14.3v 14.3v 25a 45v 25v others packing 12.9kg; 1pcs/14kg/1.98cuft dimension control wiring 466.8*283.5*100mm (l*w*h) rj11 -rs232 (option) file name:tn-3000-spec 2010-04-09 note 1.efficiency is tested by 2100w, linear load at 13v, 26v, 52v input voltage.2.output derating capacity referenced by curve 1. 3.dc current is tested by 3000w, linear load at 12v, 24v, 48v input voltage. 4.all parameters not specified above are measured at rated load, 25 of ambient temperature. 5.the tolerance of each voltage value by models is:112/212 0.5v;124/224 1v;148/248 2v ac voltage factory setting set at 110vac factory setting set at 230vac protection environment lvd none en60950-1 none e 13 105 5 95 5 95 5 90 5 85 5 85 5
inverter tn v.1.1 1. installation of tn-3000 unit and pc 2. explanation of monitoring manu 2.1 main page figure 2 1. setting: adjustment for output voltage, charging related voltag e, frequency, and operation mode. please refer to figure 3 for details. 2. statistics: calculate for the percentage of operating period for ea ch operation mode. please refer to figure 4 for details. 3. r.c. power off: power can be turned on or off at the remote location. 4. pause: stop refreshing the page of monitoring software. 5. status of unit: indicating current operating status of tn-3000. 6. signals that display current condition of the unit. db9 female figure 1 16 phone jack rj11 rj11 pin no. db9 pin no. 23 35 42 1 2 3 4 6 7 8 9 5 setting solar charge 1 2 3 4 5 6 inverter ac charge 100 100 0 0 battery voltage o/p voltage internal temperature by pass tn-3000-212 utility voltage start date reset date o/p frequency power on remote off battery low battery used up stand by saving mode abnormal shutdown battery loading 54.1 110 10.0 0.0 2010/01/01 03:13:33 pm 2010/01/01 01:40:56 pm 60.0 v v v hz ac in statistics r.c. power off pause exit file name:tn-3000-spec 2010-04-09 3000w true sine wave dc-ac inverter with solar charger t n - 3 0 0 0 s e r i e s instructions for tn-3000 monitoring software
inverter setting inverter setting 2.2 setting page 2.3 statistic page figure 3 figure 4 1. user can adjust the settings based on the characteristics of batteries b een used: equalization voltage, floating voltage, alarm voltage, and shut-down voltage. ups mode / energy saving mode selection and ac outp ut voltage and frequency can also be set in this page. 2. read: read current settings of the unit. 3. write: write the revised setting into the unit. 4. load: load in factory default settings. 1. start date: date that installing the monitoring software. 2. reset date: date that resetting the statistics. the start date will not b e influenced by resetting the statistics or turning off the unit. 3 .inverter time rate: operating period of "inverter mode" represents h ow many percent of the whole operating period. 4. bypass time rate: operating period of "bypass mode" (energy provides d irectly by the utility) represents how many percent of the whole operating period. 5. shut down rate: percentage of time period that the unit is under the conditi on of shut down. 6. solar time rate: percentage of time period that the solar charger is funct ioning after turning on the tn-3000 unit. 7. loading average: average loading after turning on the tn-3000 unit . * inverter time rate + bypass time rate + shut down rate = 100% 1 file name model name manufacture series number date of manu. revision i/o type bauds rate equalization volt. floating volt. alarm volt. shutdown volt. voltage frequency stand-by saving mode ups mode energy saving mode d:\tn_110rr\20100101\rev\tn_110rr\tnf\tn_3k0_512.tn f start date start date 2010/01/01 03:13:33 pm 2010/01/01 01:40:56 pm inverter time rate inverter time rate bypass time rate bypass time rate shut down rate shut down rate solar time rate solar time rate loading average loading average 91.2 31.9 0.0 0.0 8.8 68.1 0.0 0.0 24.7 63.7 % % % % % % % % % % tn-3000-212 meanwell loc-1234567890 rev:1.10 212 9600 14.3 13.3 11.3 10.5 v 13.5 ~ 15.0v 13.0 ~ 13.5v 11.0 ~ 11.5v 10.0 ~ 11.0v vv v 230 v 50 1 read write lead exit read ok!! hz on on on comm ports 2 3 4 off 01/01/2010 3000w true sine wave dc-ac inverter with solar charger t n - 3 0 0 0 s e r i e s file name:tn-3000-spec 2010-04-09 exit reset
type-a receptacle type country certificate type-b type-c type-d type-e type-f usa europe australia u.k japan gfci (expect for 48v input) ac output receptacle (optional) e 13 unit:mm mechanical specification derating curve a :type a outlet b :type b outlet c :type c outlet d :type d outlet e :type e outlet f :type f outlet +ac charger and solar charger true sine wave inverter 12:12vdc 24:24vdc bat. voltage: 48:48vdc 1:110vac 2:230vac output: o/p wattage:3000w tn 3000 112 a e e 13 13 curve 1 ambient temperature ( ) 0 10 20 30 40 50 60 70 20 40 60 80 100 load (%) 3000w true sine wave dc-ac inverter with solar charger t n - 3 0 0 0 s e r i e s file name:tn-3000-spec 2010-04-09 remote port c i r c u i t b r e a k e r p r e s s t o r e s e t (for receptacle) ac output ac intput ac output ac output ac intput ac output on on bat low bat low saving saving setting setting remote port ac charge ac charge solar charge solar charge ac in ac in by pass by pass inverter inverter load load 100 100 battery battery 00 100 100 00 c i r c u i t b r e a k e r p r e s s t o r e s e t (for receptacle) on off c i r c u i t b r e a k e r p r e s s t o r e s e t chassis ground cat.no.(1gg1hs-212) wire range(10-4 awg str cu soldered wires) torque (17.7-26.5 in lb) (for ac input) on off c i r c u i t b r e a k e r p r e s s t o r e s e t chassis ground cat.no.(1gg1hs-212) wire range(10-4 awg str cu soldered wires) torque (17.7-26.5 in lb) (for ac input) 31.29 31.29 13 13 type-a type-b 122.44 161.84 100 31.6 direction air flow direction air flow 273 34 12 283.5 129.63 29 reverse polarity will damage the unit. neg pos 286.2 90.3 466.8 46 7 7.5 ac input ac output fg l l n n


▲Up To Search▲   

 
Price & Availability of TN-3000-112

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X